Skip to content
Equipment selection. International supply.
B2B.engineerUSK ENERGY
044 339-50-20Call us
UKTZED 8414 / 9027 · Subgroup 04

Mine Ventilation and Gas Control: Methane, Dust, Fire

The safety of the mine does not begin at the hatch — it begins with the ventilation and gas monitoring system. We select fans according to air volume and depression, gas analyzers according to methane and CO control requirements, fire alarms taking into account ATEX requirements. For coal mines, all equipment has an explosion-proof certification.

up to 100 m³/sproductivity
ATEX Iprotection class
0-100% LELgas analysis
Equipment-type illustration: Mine Ventilation and Gas Control: Methane, Dust, Fire
Types & Configurations

Types & Configurations

Each type is a separate range of parameters and its own task. A wrong choice here leads to overspending or downtime.

Mine fans are axialMain mine fans VME-5, VME-6, VCP-7. High productivity for main products.Analogues: VME · Howden · Korfmann · Mine Master
Local ventilatorsSmall-sized for slaughter, dead ends, individual areas. VMP-5, VMP-6 with ATEX protection.Analogues: VMP · Korfmann · ABB · ATB
Gas analyzers are stationaryMethane, CO, oxygen, dust control systems. Integration with the control room, emergency notification.Analogues: Trolex · Senova · GMI · UralKKM
Gas analyzers are portableIndividual detectors for teams. CH4, O2, CO, H2S are disposable and reusable.Analogues: BW Honeywell · Drager · MSA · GMI
Fire alarmATEX smoke and temperature sensors, communication lines, control panels, evacuation equipment.Analogues: Hochiki · Drager · UralKKM
What to Ask in RFQ

Parameters Without Which Selection Does Not Start

Fan performancem³/s, at a given depression. Large mines - up to 100 m³/s.
DepressionPa, the pressure that the fan creates in the mine. Depends on the length of the products.
Protection classATEX I (mining), for coal mines. ATEX II — for oil and gas.
Accuracy of the gas analyzer±2% LEL for methane, ±2 ppm for CO. Mirror range 0-100% LEL.
IntegrationModbus, Ethernet, special protocols of mine control rooms.
Where Delivery Works

Typical Applications

Donbas coal minesLarge axial VME-6, methane gas analyzers, local ventilation of the bottoms.
Ore minesAxial VCP-7, CO and dust gas analyzers, fire alarm.
Granite and limestone quarriesLocal ventilation of crushing and sorting shops, dust control.
Mining structuresTemporary ventilation of tunnel works, monitoring of CO gases from blasting works.
Market Overview

What is Actually Ordered in Ukraine

Mine ventilation and safety is the highest responsibility in mining equipment. European (Howden, Korfmann, Drager) and Polish (Mine Master) manufacturers hold the premium segment with full ATEX certification and experience in severe emergency situations. VME and VMP are critically important for Ukrainian coal mines — old Soviet models and new Ukrainian ones (Svet Shakhtarya, Artemzalizomash) work well with the local infrastructure. For non-methane ore mines, less requirements, more options.
Frequently Asked Questions

FAQ

Can a conventional fan be used in a coal mine?

No. Only ATEX-certified class I (mining) equipment. Normal is a guaranteed accident at the first accumulation of methane.

How much does a complex of gas analyzers for a mine cost?

Include the model or specifications, quantity and delivery location. We will confirm price, availability and lead time in our reply.

What is the resource of the VME-6 mine fan?

20-30 years with proper maintenance: annual revision of bearings, balancing of the rotor, inspection of blades. Overhaul every 8-10 years.

Who conducts operator training?

Engineers of the equipment manufacturer in a complex with local training centers of Derzhhirpromnadzor. Certification is mandatory.