Warehouse Racks: Pallet, Drive-in, Gravity, Mezzanine

Structure skeleton. We select the type of rack for the product (weight, dimensions, turnover) and service technique. Pallets are the most popular format for a typical warehouse with a reach truck. Drive-in - for one product with low turnover (FILO). Gravitational - for FIFO. Mobile - for high densities. Mezzanines - for small artificial goods.

up to 12 mheight
100-2500 kgpallet
FIFO / LIFOmodes
Equipment-type illustration: Warehouse Racks: Pallet, Drive-in, Gravity, Mezzanine

The warehouse racking system is a structure for storing pallets or artificial goods in height, and not only on the floor: frontal ones give direct access to each pallet, packed and gravity ones save space at the cost of selectivity, push-back and cantilever ones cover intermediate tasks. The choice of type depends on the turnover of the product and the maintenance technique, and not only on the height of the ceiling.

Push-back racking with pallets in an industrial warehouse · photo: Tiger Lily / Pexels
Types & Configurations

Types & Configurations

Each type is a separate range of parameters and its own task. A wrong choice here leads to overspending or downtime.

Pallet racksUniversal for storing pallets with equipment. Height up to 12 m, span width 1800-2700 mm.Analogues: Mecalux · SSI Schäfer · Jungheinrich · Stow
Drive-in / stampedWithout aisles between racks. High density, LIFO. For the same type of product with low turnover.Analogues: Mecalux · SSI · Stow
Gravitational rollersPallets move by gravity. FIFO mode. For food, pharmaceuticals, expiration dates.Analogues: SSI · Mecalux · Interroll
Mobile (Movirack)Shelves on wheel supports. 1 pass per block of 5-10 racks. High density + access to every pallet.Analogues: Mecalux Movirack · SSI Mobile · Stow
Mezzanines and mezzaninesMulti-level platforms for small artificial goods. Up to 4 tiers, with elevators and conveyors.Analogues: Mecalux · Konstant · Stow
What to Ask in RFQ

Parameters Without Which Selection Does Not Start

Rack typePallet, stuffed, gravity, mobile, mezzanine. Depends on the product and equipment.
HeightUp to 12 m depending on the equipment and security requirements. Standard 6-8 m for basic projects.
Load capacity of the shelf100-2500 kg. Picked up with a 20% margin to the actual weight of the pallet + goods.
Protective elementsProtection of racks from reach trucks, anti-rebound barriers, anti-fall protection of the upper tiers.
CertificationFEM 10.2.02, EN 15512, EN 15620. Without certification, firefighters and inspectors will not accept.
Where Delivery Works

Typical Applications

Logistics hubPallet racks 8-10 m with reach trucks, aisle width 2.8 m.
Food compositionGravity roller with FIFO control for expiration dates.
Industrial composition of raw materialsDrive-in for the same type of product (grain, fertilizers, raw materials) with low turnover.
Small artificial storeMezzanine rooms with elevators for collecting orders by the operator.
Market Overview

What is Actually Ordered in Ukraine

European Mecalux (Spain), SSI Schäfer (Germany), Jungheinrich (Germany), Stow (Belgium) hold the premium segment. Ukrainian and Polish manufacturers (Konstant, Stiplast, ELDIS) - standard for typical warehouse projects, with full EN certification. Turkish - middle segment. The key when choosing is the correct calculation of the weight and dimensions of the pallets, the width of the passage for the equipment, the height for the building. Without design, there is a risk of installing racks that will not pass a fire inspection or that your equipment will not be able to service.

Push-back and cantilever: types that are missing from the standard list

In addition to pallet, packed, gravity and mobile racks, there are two more formats for specific tasks.

Push-back is a hybrid of push-back and gravity: pallets stand on carts that roll along inclined rails deep into the rack. A new pallet has been loaded - it pushes the previous one further, it is always unloaded from the front edge. Unlike drive-in, there is no need to drive a forklift into the frame — it is faster and safer for racks, the depth is usually 2-5 pallets.

Cantilever racking does not have vertical racks in the storage area - the load rests on consoles protruding from the central column. This format is not for pallets, but for long cargo: pipes, profiles, boards, fittings, rolled metal. Capacity is calculated not by cubic meters, but by linear meters of the console and the distance between levels. The consoles are one-sided (along the wall) and two-sided (in the center of the room, the load on both sides of the column) — the extension of the console and the step between the columns are selected for the longest unit of load, and not for the average one.

FIFO or LIFO: How shelf physics determines product turnover

The gravity rack FIFO is built into the design: the pallet is loaded from the upper (rear) end of the inclined channel, it rolls down, and is always taken from the lower (front) — that is, the oldest pallet cannot physically be behind the new one. This is critical for food products, pharmaceuticals and everything with an expiration date.

In drive-in and push-back, it is the opposite of LIFO: the loader drives into the channel and places a pallet on top of or in front of the already existing ones, you can pick up only the one that entered last. For a homogeneous product without a strict expiration date (raw materials, building materials, packaged products of the same lot), this is not a problem - the turnover still goes in batches. Front racking gives direct access to any pallet regardless of loading order, so FIFO or LIFO there is a matter of warehouse organization, not design.

Load per tier and storage density

Indicative ranges for preliminary calculation — exact numbers are given by an engineering calculation for a specific product.

Rack typeLoad on tierStorage densityDirect access to the palette
Front (pallet)2000-6000 kg per pair of beamsModerate, suitable for passageways for equipmentYes, to each
Drive-in1500-4500 kg per canalHigh, without passages between rowsNo, last out only (LIFO)
Gravity (flow-rack)1500-4000 kg per canalHigh, due to the depth of the channelNo, automatic FIFO
Push-back1800-5400 kg per canalAbove average, 2-5 pallets deepPartial, LIFO by channel
Mobile (Movirack)like the front one, 2000-6000 kgVery high, one pass per blockYes, with the opening of the passage
Console500-2500 kg per consoleCalculated in ch. m, not in volumeYes, complete

By what criteria is the type of rack chosen

Product turnover

High turnover and a diverse assortment — only frontal with direct access; low turnover of one product — drive-in or push-back gives density without loss of speed.

Expiry date and party

If it is critical not to mix up the parties, gravity FIFO removes this issue constructively, not organizationally.

Type and width of passages for equipment

A reach truck, a picker or a narrow-aisle stacker determine the minimum width of the passage and, as a result, the density of placement.

Room height and equipment

A rack higher than 10-12 m requires narrow-passage equipment with guides - this is a different cost and a different logic of passageways.

Dimensions and uniformity of cargo

Long rolled products or pipes - cantilever only; pallets of different sizes in one row are a reason to abandon the drive-in.

Budget and delivery terms

Front racking is cheaper and faster in delivery; mobile powered systems add cost and time through rail base certification.

DSTU EN 15635: why the rack is inspected, even if it did not fall

DSTU EN 15635 regulates not the design, but the operation of already mounted racks: who inspects them and how often. The standard provides for three levels of control — a permanent visual inspection by warehouse staff, a periodic inspection by a responsible person of the enterprise (usually quarterly) and an expert inspection by an external specialist at least once a year.

Damages are classified by the color of risk: green zone — the defect is recorded, observe; yellow (orange) — remove within a specified period, usually up to several weeks; red - unload the tier immediately and take the rack out of service for repair or replacement. Without such an inspection log, the insurance company has a formal reason to refuse payment after the incident, even if the reason is not the rack itself.

What happens when the forklift hits the rack

The rack deforms non-linearly

A deflection of only 5-6 mm per meter of rack length can reduce the load-bearing capacity by tens of percent - it is not visible to the eye.

The paint hides the crack

The impact often peels off only the paint, and the cold-formed steel itself gets dented; without measuring with a ruler and level, the defect is passed.

It is impossible to brew a damaged rack

Welding changes the structure of the metal and removes the factory certification of the element — according to EN 15635, a damaged rack is only replaced, not repaired.

Defensive corners take the hit on themselves

A separate bumper near the floor costs many times less than one rack replacement and does not require the site to be stopped for repairs.

The tier must be unloaded before the investigation

A loaded, damaged layer can hold weight for weeks, and then collapse from a nearby shock, so unloading is immediate, not planned.

Frequently Asked Questions

FAQ

What is the type of rack for a typical warehouse?

Compare configurations by operating parameters, materials, compatibility and scope of supply. Establish purchase-price and operating-cost differences from quotations based on the same requirements.

What height is optimal?

Depends on the technique and the height of the building. The standard is 8-10 m for most warehouses. If there is an opportunity, 10-12 m is advantageous in terms of density. 12+ m - special equipment and requirements.

How much does a pallet rack for 1000 pallets cost?

Include the model or specifications, quantity and delivery location. We will confirm price, availability and lead time in our reply.

Do you do design and certification?

Yes. Engineering calculation, drawing, specification, FEM/EN certification. Without this, the object will not be accepted.

How do gravity racks differ from push-back?

Gravity racking is an inclined channel with rollers where the pallet rolls by itself under its own weight, loading and unloading from different ends, i.e. pure FIFO. Push-back is carts on inclined rails: a new pallet is pushed from above, it pushes the previous ones deeper, and it is always taken from the same front edge, i.e. LIFO. Push-back does not require equipment to enter the channel, gravity — has no moving parts at all.

What is included in warehouse systems for storing pallets?

A warehouse storage system is a rack structure (frame, racks, beams, decking), protective elements (corners of racks, anti-rebound barriers, anti-fall net of upper tiers) and maintenance equipment for a specific type of rack (reach truck, order picker, narrow aisle stacker). Without coordination of all three parts for one project, the rack is either not used to its full height, or the equipment cannot reach the distant pallets.

What kind of warehouse equipment is needed besides the racks themselves?

In addition to the rack structure of the warehouse, you need: lifting and transport equipment for the height and width of the aisles (reach truck, stacker, loader), protective elements of racks and ends of rows, a system for marking storage places (addressing for WMS) and, for a height of more than 8-10 m, guide rails or wire for narrow-passage equipment. The omission of any of the points is usually detected already after the installation of the racks.

What warehouse equipment is needed for stuffed racks?

Drive-in racks require a loader or reach truck capable of driving inside the frame between the racks — and these are narrower forks and a smaller turning radius than for front racks. The width of the passage between the racks inside the channel is laid for a specific model of equipment at the design stage, otherwise the driver simply will not drive the loader into the channel without hitting the racks.

What is DSTU EN 15635 and is inspection of racks mandatory?

DSTU EN 15635 is a standard for the operation and maintenance of racking systems: it provides for constant visual control by personnel, a quarterly inspection by a responsible person of the enterprise and an annual expert inspection by an external specialist. Formally, this is not always a direct legal requirement, but insurance companies and lessors of warehouse space are increasingly asking for an inspection log as a condition of the contract.

What to do if the forklift hits a rack post?

First, unload the damaged and neighboring tiers without waiting for the conclusion - a deformed rack can hold weight for weeks, and collapse suddenly. Next, measure the deviation from the vertical: a deflection of more than a few millimeters per meter of length is grounds for decommissioning the section. A damaged rack according to EN 15635 is replaced entirely, it cannot be brewed or straightened - this removes the element's certification.

How does a cantilever rack differ from a regular pallet rack?

Cantilever racking does not have vertical racks in the storage area — the load rests on consoles protruding from the central column in both directions. It is not intended for pallets, but for long-dimensional loads: pipes, profiles, boards, rolled metal, which simply do not fit lengthwise on a pallet rack. The capacity of the cantilever rack is calculated in linear meters, not in the number of pallet spaces.

How many pallets does a deep push-back rack hold?

The standard push-back depth is from 2 to 5 pallets in one channel, rarely up to 6 with a reinforced cart frame. Greater depth increases storage density, but reduces the number of SKUs available simultaneously from a single aisle - so push-back is chosen for a product with a moderate number of items and an average turnover, rather than a wide assortment.