Industrial chillers: air and water-cooled, freecooling

The chiller is the heart of process cooling: from data centers to pharmaceutical reactors. We select air chillers up to 500 kW (compact, without cooling tower), water chillers up to 2000+ kW (with external cooling tower, the best efficiency), with free cooling for the Ukrainian climatic zone (5-7 months of compressor-free operation), with heat utilization for hot water supply to a plant or greenhouse.

Equipment-type illustration: Industrial chillers: air and water-cooled, freecooling

Technical parameters

Cold performance
30 kW – 2 MW
Cold carrier
Water, glycol 25/35/45%
Compressor type
Scroll, Screw, Centrifugal
COP
3.5 – 5.5 (with freecooling up to 8+)
Refrigerant
R-454B, R-513A, R-1234ze
Management
Modbus, BACnet, ModRTU

Air vs water chiller

Air - in a compact case with fans on the roof or in the area next to the building. Simple installation, does not require a cooling tower. Efficiency is lower, especially in summer. Water is more powerful, with a remote condenser (cooling tower), the efficiency is 15-25% higher, but it requires a cooling tower, a pumping station, and water treatment.

Freecooling — savings on the refrigeration cycle

In Ukraine, from November to April, the outside temperature is low enough to cool the water without starting the compressor cycle. The chiller with freecooling switches to the mode of direct heat exchange with outside air, the efficiency increases by 3-5 times. The payback of the freecooling function is 2-4 years due to electricity.

Refrigerants 2025+: what to change, what not

The old R-410A and R-22 are no longer purchased in the EU. New refrigerants are R-454B (GWP 466), R-513A (GWP 631), R-1234ze (GWP 7). When choosing a new chiller, you MUST design it for R-1234ze or R-454B, otherwise after 5-7 years there will be a problem with maintenance.

Frequently Asked Questions

How to choose the chiller capacity?

Calculation: we summarize the heat release of the equipment (passport data servers, production lines), plus heat from insolation of the room (for a data center 100-200 W/m²), plus heat inflows from people (90-120 W/person). We add 15-20% of the stock. Without calculation, it is dangerous to overpay or underbuy.

Is a backup chiller needed?

For data center, non-stop production lines, food facilities - mandatory. Scheme N+1 (one spare). For office facilities, zone conditioning is optional, you can limit yourself to a partial reserve.

What about maintenance?

Planned: 2 times a year — pressure check, heat exchanger cleaning, water content control. Once every 3-5 years — replacement of refrigerant and overhaul of compressors. We do it ourselves or choose a local service partner.

How quickly will we put?

Series from 30 to 300 kW — 6-10 weeks. Large (500+ kW) with configuration — 12-18 weeks. Emergency replacement is a separate priority track.

BUYER’S BRIEF

Inputs for an accurate equipment selection

Start with these details. Mark any unknown requirement in your enquiry so it can be clarified before a model is selected.

Select the information you already have

Check the full order code, contents, technical compliance, exclusions, documents, warranty terms and lead time in the offer. Price and availability are confirmed for your order.

Prepare an equipment enquiry

The form opens with the topic and your checklist. Nothing is sent until you submit it.

USK Energy

Find the right equipment

Leave your contact details. A manager will clarify the specifications and prepare a quotation.

Or contact us directly: sales@usk.ua · 044 339-50-20