Fiber Optic Cables: Backbone, Plant, Data Center
Optics are a critical component of modern industrial networks, data centers and carrier communications. We select single-mode cables for long links (from 1 to 80 km), multimode OM3/OM4/OM5 for workshops and data centers, armored with corrugated steel tape for external laying, flexible for robotics. Connectivity - cross panels, patch cords, couplers, OTDR testing.
Technical parameters
- Type of fiber
- SM 9/125, MM OM3/OM4/OM5
- Number of fibers
- 2 / 4 / 8 / 12 / 24 / 48 / 96
- Outer shell
- PE, LSZH, FR, armored
- Bending radius
- From 80 mm
- Working temperature
- −40 °C … +70 °C
- Standards
- ITU-T G.652, G.657, OM3-5
Single-mode vs multi-mode: when and what
Single-mode (SM) — for all distances from 500 m, for long links, for communication between buildings and cities. Multimode (MM) - only up to 500-1000 m, but cheaper transmitter equipment (vCSEL instead of lasers). In the data center, OM4 is now becoming the standard for 100 GbE up to 100 m.
Welding vs mechanical connectors
Welding is the lowest loss (0.02-0.1 dB), a standard solution for all permanent installations. Mechanical connectors (Fast Connect) — for temporary or field repairs, loss 0.5-1 dB. Planned installations — welding only.
OTDR testing is a must
Before handing over the track, we conduct OTDR testing from both ends. The document is an optical passport of the line with an attenuation curve, a list of welded joints and their losses. Without this passport, the telecommunications operator does not accept the cable.
Frequently Asked Questions
What is the difference between OM3 vs OM4 vs OM5?
OM3 — 100 GbE to 100 m, core data center fiber. OM4 - 100 GbE up to 150 m, 400 GbE up to 100 m. OM5 - new, with SWDM, allows 4 channels on one fiber. For a new data center — OM4 or OM5.
Is it possible to lay the optics together with the power cable?
It is possible, but with limitations. Optics are not sensitive to EMI (this is their advantage), but mechanical loads are critical. Therefore, in one tray - yes, in a common corrugation - no (the power cable can suppress the optical one when buried).
How to store an optical cable on a drum?
Original drum + dry room with temperature control −20 ... +40 °C. Drums cannot be placed horizontally (the fiber shifts), and they cannot be stacked on top of each other.