Operator HMIs, Industrial PCs, Network Interfaces
The interface between the machine and the person. We select the HMI according to the screen size, the number of communication tags with the PLC, the specifics of the production environment (humidity, vibration, temperature). Industrial PCs - for complex tasks of visualization, machine vision, AI analytics. Network gateways - for integration of various protocols and extraction of data into the IT network.

The HMI (Human-Machine Interface) panel is a 4- to 22-inch touchscreen display that shows process status and accepts operator commands, connected to a PLC via Modbus TCP, Profinet, or EtherNet/IP. A resistive sensor is cheaper and works with gloves, a capacitive sensor is more accurate and supports multi-touch. An industrial PC takes over the more complex logic when the HMI capabilities are no longer enough.
Types & Configurations
Each type is a separate range of parameters and its own task. A wrong choice here leads to overspending or downtime.
Parameters Without Which Selection Does Not Start
| Diagonal and resolution | 4-22", VGA / SVGA / FullHD. A larger screen means more information at a glance. |
| Touchscreen type | Resistive - cheaper, works with gloves. Capacitive - more accurate, faster response. |
| Number of communication tags | 250-50000 with PLC. It is selected by the number of variables that are displayed and archived. |
| Protocol support | Modbus, ProfiBus, EtherCAT, OPC UA, MQTT for IIoT. |
| Working conditions | -20...+60°C, vibration 1-2g, IP65/IP66 on the front side. |
Typical Applications
What is Actually Ordered in Ukraine
Development Environment: Why rebranding a panel costs more than the panel itself
The hardware part in the specification is one line. Brand-specific software is what determines how long it will take to set up.
Each HMI manufacturer supplies its own development environment, and projects are not automatically transferred between them. Siemens uses WinCC Basic or Comfort within the TIA Portal, the same platform as for the S7 PLC, so screens and tags are logically linked to the controller program. Weintek develops in EasyBuilder Pro, a simpler environment popular for its low entry threshold and free license. Pro-face works through GP-Pro EX, Delta through DIAScreen or Screen Editor depending on the series of panels, B&R through Automation Studio with mapp View module.
The practical consequence for the customer is not the price of the panel itself, but the cost of the transition. The project of screens, recipes and alarms, made in TIA Portal under Siemens, will not be opened in EasyBuilder Pro for replacement with Weintek: logic, mnemonics and links to tags are processed anew. If the facility already has a fleet of HMIs of the same brand, it is cheaper and faster to stay in it, even when a competitor offers a panel that is cheaper on paper.
HMI Ethernet protocols: Modbus TCP, Profinet, EtherNet/IP
The three protocols solve the same problem — communication between the panel and the controller over the network — but are tied to different manufacturers' ecosystems.
| Protocol | Ecosystem | Feature | When selected |
|---|---|---|---|
| Modbus TCP | Manufacturer-neutral | Simple, available in any PLC and encoder with an Ethernet port | A mixed fleet of equipment from different manufacturers |
| Profinet | Siemens | Real time, deep integration with S7-1200/1500 | The facility is built on Siemens from PLC to drives |
| EtherNet/IP | Rockwell / Allen-Bradley | CIP protocol on top of standard Ethernet | Lines and machines on Allen-Bradley controllers |
| OPC UA | Manufacturer-neutral, upper level | Platform-independent exchange with MES/ERP, built-in security | Transferring data from the shop to the control room or the cloud |
Resistive or capacitive sensor
On paper, the difference is in a few lines of characteristics, in production - in whether the operator can handle it in work gloves.
Work in gloves
Resistive responds to any pressure, including a glove or stylus. Capacitive by default only recognizes a bare finger or a special conductive glove.
Calibration stability
A resistive sensor is a membrane that loses accuracy over time and the number of presses and requires recalibration. Capacitive has no moving layers and does not wear out in the same way.
Multitouch and gestures
Only capacitive supports zooming with two fingers and recognition of multiple simultaneous touches — resistive technology is not physically designed for this.
False alarms from moisture
A drop of condensate or process liquid on the capacitive screen can simulate a touch. In wet shops and washing areas, a resistive sensor is often more reliable, despite the outdated appearance of the technology.
Compatibility with protective film
Resistive panels calmly accept an additional protective film on top of the glass - sensitivity does not noticeably decrease. On the capacitive sensor, a thick film or dirt on it weakens the signal and can cause touch failures.
IP65 on the front panel and operating temperature range
Two parameters that are most often confused when choosing a place of installation.
IP65 only applies to the front
Protection against dust and water jets applies to the front panel behind the glass. The back of the housing with cables and board is usually only IP20 and requires mounting inside the cabinet.
A separate class is required for the street
IP65 is not designed for direct rain and sun - for outdoor installation, take a panel with IP66/IP67 or an additional visor and heat the housing at sub-zero temperatures.
The working range of -20...+60°C is not always suitable
Near stoves, dryers or outside in winter without cabinet heating, this range is exceeded in both directions — a special design with an extended range or forced cooling or heating of the cabinet is required.
Resolution for screen size
At 4-7 inches, basic SVGA is enough - you still can't see the details. FullHD is justified from 15 inches and more, when several mnemonics or detailed trends are displayed on the screen at the same time.
HMI on the market: where Siemens is justified, and where overpayment
The brand of the panel rarely determines the functionality by itself — more often it is determined by which PLC and which team is already setting up the project.
Siemens Comfort Panels dominate where the controller is already an S7-1200 or S7-1500 — the common TIA Portal ecosystem reduces commissioning time, so these panels appear in specifications even for simple tasks where a cheaper alternative would suffice. Weintek and Delta cover the same functionality - mnemonic, trends, accidents, recipes - at a significantly lower cost of the panel and are justified where the PLC is also not a premium brand or the installation team is already used to EasyBuilder Pro.
Advantech and Beckhoff in this list are not HMI-panels, but industrial PCs: where full-fledged SCADA is displayed on the screen at the same time, an archive of thousands of tags is maintained or something heavier than a mnemonic is calculated - for example, an image from a camera - the panel is no longer a panel, but a computer with a touchscreen instead of a monitor.
FAQ
HMI or Industrial PC?
HMI - for basic visualization and machine control (up to 1000 tags). Industrial PC - for complex tasks, integration with ERP/MES, machine vision, AI.
Can I replace an old Siemens HMI with a new one?
Yes, with project migration via WinCC Comfort. The old series of Touch Panels - to Comfort Panels. The basic logic is carried over, the graphics are carried over with adaptation.
What is the diagonal for the workshop cabinet?
7" or 10" is sufficient for a base cabinet. 12-15" for cabinets with a large number of objects. 22" - for the central control room.
How much is the HMI Siemens Comfort 10"?
Include the model or specifications, quantity and delivery location. We will confirm price, availability and lead time in our reply.
What is an HMI panel?
HMI (Human-Machine Interface) is a touch panel that shows the operator the state of the equipment and the process and accepts control commands instead of physical buttons and indicators. It is connected to a PLC via Modbus, Profinet or EtherNet/IP, the diagonal is selected according to the amount of information on the screen — from 4 inches for a separate machine to 22 inches for the control room.
What development environment is required for a Weintek or Delta HMI panel?
Weintek is programmed in EasyBuilder Pro, a free environment with a low entry threshold. Depending on the series of panels, Delta uses DIAScreen or its own Screen Editor. Both are different from the TIA Portal, in which Siemens Comfort Panels are configured, so the project of screens under one brand is not automatically transferred to another.
How does Profinet differ from Modbus TCP for HMI to PLC connection?
Modbus TCP is a vendor-neutral protocol that works with any controller that has an Ethernet port. Profinet is a protocol of the Siemens ecosystem with real-time operation and deeper integration with S7-1200/1500: module diagnostics and data exchange without additional configuration of registers, as in Modbus. In a facility with a mixed fleet of equipment, Modbus TCP remains the simpler common denominator.
Is the resistive sensor of the HMI panel suitable for working with gloves?
Yes, and this is its main advantage over the capacitive one — the resistive membrane reacts to any pressure, including a glove or a stylus. The price for this is that the membrane wears out over time and loses calibration accuracy, and the resistive sensor does not support multitouch and gestures.
What does IP65 protection mean on the HMI front panel?
IP65 means complete protection against dust and water jets from any direction, but only applies to the front side of the panel behind the glass. The back end with the board and cables is usually only IP20 and requires installation inside the control cabinet, not exposed to the street or in the wash area.
What resolution is required for a 15 inch HMI panel?
From 15 inches and more, FullHD is justified - such a screen simultaneously accommodates several mnemonics, detailed trends or a tab with an alarm archive, and the low resolution will make small text unreadable. On panels of 4-7 inches, the basic SVGA is quite enough: the details there are still not visible due to the physical size of the screen.
Is it possible to connect an HMI panel of one manufacturer to a PLC of another brand?
Yes, if both support a common protocol — most often Modbus TCP or Modbus RTU, implemented in almost all PLCs and panels regardless of brand. It is more difficult with proprietary protocols such as Profinet or EtherNet/IP — they are also open in terms of specification, but require a separate driver or module in another manufacturer's panel.